Quality Magazine logo
search
cart
facebook twitter linkedin youtube
  • Sign In
  • Create Account
  • Sign Out
  • My Account
Quality Magazine logo
  • NEWS
  • PRODUCTS
    • SUBMIT YOUR PRODUCT
  • CHANNELS
    • AUTOMATION
    • MANAGEMENT
    • MEASUREMENT
    • NDT
    • QUALITY 101
    • SOFTWARE
    • TEST & INSPECTION
    • VISION & SENSORS
  • MARKETS
    • AEROSPACE
    • AUTOMOTIVE
    • ENERGY
    • GREEN MANUFACTURING
    • MEDICAL
  • MEDIA
    • A WORD ON QUALITY PUZZLE
    • EBOOK
    • PODCASTS
    • VIDEOS
    • WEBINARS
  • EVENTS
    • EVENT CALENDAR
    • QUALITY SHOW
    • IMTS
  • DIRECTORIES
    • BUYERS GUIDE
    • NDT SOURCEBOOK
    • VISION & SENSORS
    • TAKE A TOUR
  • INFOCENTERS
    • NEXT GENERATION SPC & QUALITY ANALYTICS
  • AWARDS
    • ROOKIE OF THE YEAR
    • PLANT OF THE YEAR
    • PROFESSIONAL OF THE YEAR
  • MORE
    • eNEWSLETTER
    • INDUSTRY LINKS
    • THE LEADERSHIP SURVEY
    • CLASSIFIEDS
    • MARKET RESEARCH
    • PRODUCT SPOTLIGHTS
    • QUALITY STORE
    • WHITE PAPERS
  • EMAG
    • eMAGAZINE
    • ARCHIVES
    • CONTACT
    • ADVERTISE
  • SIGN UP!
NDT

NDT | Thermography

Validating Thermography System Performance

The combination of advanced infrared camera technology and dedicated software analysis tools has made active thermography a viable alternative to traditional methods.

By Steven M. Shepard Ph.D.
Modern systems integrate all functions into a single handheld unit.

An Active Thermography system combines an IR camera that measures surface temperature with excitation and processing components to detect subsurface defects. Modern systems (right) integrate all functions into a single handheld unit. Image Source: Thermal Wave Imaging, Inc.

Active Thermography System: Excitation, IR Camera, Processing PC

An Active Thermography system combines an IR camera that measures surface temperature with excitation and processing components to detect subsurface defects. Modern systems (right) integrate all functions into a single handheld unit. 

Image Source: Thermal Wave Imaging, Inc.
Modern systems integrate all functions into a single handheld unit.
Active Thermography System: Excitation, IR Camera, Processing PC
January 4, 2025
✕
Image in modal.

Active thermography (AT) has become a popular method for nondestructive testing, quality control and material characterization that is widely used in the aerospace, automotive and power generation industries. The combination of advanced infrared (IR) camera technology and dedicated software analysis tools has made AT a viable alternative to traditional methods for many applications, offering contact-free, wide area subsurface inspection capability that is robust enough to accommodate production environments. However, as companies integrate thermography into their quality programs, they may be unfamiliar with the technology, and encounter challenges when trying to validate and document the performance of a thermography system to ensure that all components are operating within their specified ranges. In this article, we will review the basic principles of AT, and discuss how it is being used in industry today and the process of integrating it into an organizational quality system.

How It Works

While there are numerous variations in how energy is applied (pulsed, step, modulated) and the data is analyzed (time / frequency domain), they are all based on the same fundamental principles of thermal diffusion. The surface of a part is heated, and cools as the applied heat propagates into the structure. The presence of an internal defect (e.g. void, delamination, inclusion) or structure (e.g. joint, spar, substrate) interferes with normal thermal diffusion process. The entire heating and cooling process is monitored by an IR camera, so that an internal defect or feature with a lower thermal conductivity than the surrounding host material (e.g. a void) will obstruct the inward flow of heat and cause a transient “hot spot” to appear in the IR image of the surface in the vicinity of defect. The opposite result occurs when a low thermal conductivity feature (e.g. a metal stiffener) absorbs inbound heat and generates a cold spot on the surface. Although simple hot/cold spot detection is not sufficiently sensitive to accommodate most modern industrial inspection requirements, dedicated signal / image processing are routinely used to increase range and sensitivity, and provide measurement of material properties.

An operator reviews results of an automated AT inspection of aircraft turbine blades.
An operator reviews results of an automated AT inspection of aircraft turbine blades. Image Source: Thermal Wave Imaging, Inc.

Anatomy of an Active Thermography System

Used alone, an IR camera has limited utility for QC / NDT applications. In addition to the IR camera, which measures the surface temperature of the part, detection, measurement or characterization of subsurface defects or material properties requires thermal excitation of the part under test, as well as processing and analysis of the image output data from the IR camera. Taken together, excitation, temperature measurement, and processing functions comprise an AT system, which can be as simple as a human inspector using a handheld IR camera and heat gun or even the sun and his/her eye, brain and experience to interpret the camera images to find water trapped in an aircraft control structure, or as complex as the fully automated flash thermography systems used to test spot welds, measure coating thickness or evaluate solar cells in modern manufacturing. For reliable and accurate AT results, it is essential that each of these system functions are appropriate for a particular application, and that they function properly individually, and together as a system.

Excitation: A transient thermal excitation is uniformly applied to the surface of a part using light, forced air, direct contact or electromagnetic radiation. The excitation may be a brief pulse from a flashlamp or laser that lasts for a few milliseconds or less, or a longer one lasting several seconds from a heat lamp or hot air gun. The excitation may also be modulated or scanned across the surface of the part, either in close proximity or at a standoff distance of several feet. Optical sources are most widely used in industry as they are relatively easy to control spatially and temporally. For a particular application, the source must couple effectively (e.g. be absorbed, and not reflected) and operate on an appropriate time scale. As an example, heat transfer in an aluminum part occurs in milliseconds, appropriate for a flash or pulsed laser source. However, in the same part in fiberglass, heat travels the same distance in several seconds, so that a heat lamp could be used effectively.

Temperature Measurement: An IR camera measures IR radiation from the surface of an object, which is a function of its temperature. It does not “see through” most industrial materials, but it can be used to infer subsurface structure when it is used with a thermal excitation source to heat the surface of a sample. Cameras vary in sensitivity (usually expressed as Noise Equivalent Temperature Difference, or NETD), wavelength range, frame rate and the number of pixels in the focal place array sensor. The “best” camera for a particular application is one where the wavelength is sensitive to temperature change in the material of interest, the frame rate is high enough to capture the cooling response to the stimulation being used, and the pixel density is sufficient to detect the minimum required defect size. Uncooled microbolometer cameras are small, inexpensive low-maintenance devices that operate in the 8-14 mm spectral range. They measure the change in resistance as IR radiation is absorbed by an array of small sensors, which is then correlated to temperature. However, measurement or detection of deeper, or subtler, defects may require the greater sensitivity of larger, cryogenically cooled cameras, which are quantum devices that collect incident IR photons, operating in either the 2-5 or 8-14 mm range.

Processing / Analysis: Modern AT systems use a dedicated PC to process data from the IR camera and present it in a format where it can be analyzed by an inspector or automatically with additional software. Widely used processing approaches techniques (Thermographic Signal Reconstruction, Principal Component, and Pulse Phase) analysis all provide consistent, repeatable results with significantly greater sensitivity than unprocessed images from the IR camera. In most cases, the techniques offer similar performance, however they may vary in terms of processing time, quantitative measurement capability and ease of interpretation.

A System Performance Validation (SPV) kit uses an engineered reference sample and software installed on the AT system to provide a daily summary of critical system parameters.
A System Performance Validation (SPV) kit uses an engineered reference sample and software installed on the AT system to provide a daily summary of critical system parameters. Image Source: Thermal Wave Imaging, Inc.

Evaluating AT System Performance

IR cameras have been widely used for many years in predictive and preventative maintenance, where a single image showing the steady state temperature of a part or machine may be sufficient for diagnostics. Since the IR camera is the only instrument required, it needs to be maintained and calibrated per the manufacturer’s requirements for optimal operation. The situation is more complex in AT; in addition to the IR camera, there is a thermal excitation source and in most modern AT systems, a computer performing additional signal processing to increase sensitivity and enable automation and measurement of subsurface features. When combined in an AT system, several conditions that involve camera, excitation and processing must be met:

  • Excitation Uniformity: Spatial variation of the excitation should cover the target area with less than a specified degree of variation (e.g. 10%).
  • Excitation Level: The amount of energy delivered to the sample should be greater than some minimum threshold level.
  • Camera Response to Excitation: AT systems collect a sequence of images to capture the response of a part over time. The response of a single pixel temperature-time history for a given part should be repeatable and consistent with modeled response for the particular part and type of excitation. For example, for a 0.5” flat metal plate the early segment of the time history view on a log-log scale should be a straight line with slope -0.5.
  • Signal to Noise: Results for programmed subsurface features should yield consistent signal to background ratios above a minimum acceptable threshold.
  • Flaw Size Measurement: The system software should accurately measure the size of programmed defects to a specified degree of accuracy.

Integrating Active Thermography into a Quality Program

Once technical feasibility has been established for a particular application, the process of implementing and adopting AT into an organizational quality program is identical to that of other NDT technologies. There are several companies that specialize in Level 1-3 AT specific training in accordance with ASNT TC-1A or NAS-410, and there are guidelines for developing AT standard practices and procedures (e.g. ASTM E2582-21.) However, a question that often comes up once AT is operational is how to track and validate system performance on an ongoing basis? Companies using IR cameras for maintenance or very basic NDT/QC tasks have relied on application-specific NDT reference standards and annual calibration by the camera manufacturer, but that may not be adequate for a modern AT system used in measurement, automated or high-volume production. In addition to the camera, the excitation and processing elements of the system must also be functioning properly.

One recent answer has been the use of a System Performance Validation (SPV) kit, which incorporates a reference sample and dedicated software for use with the AT system. Unlike an NDT reference standard, which is constructed to mimic a particular defect or condition (e.g. void, crack, inclusion), the validation standard is engineered to allow measurement of specific AT system performance metrics that should remain invariant for a properly functioning system. Ideally, the baseline settings for acceptable performance are established by the manufacturer or during initial acceptance of the AT system. The SPV test, which requires only one to two minutes, would be run daily, or at the beginning of every shift, generating a report grading the state of all critical system functions as PASS or FAIL, with a numerical value indicating where they fall relative to the acceptance range. Daily reports may be logged so that system performance can be tracked over time and maintenance (e.g. replacement of lamps, camera calibration) can be scheduled without interruption of normal production.

Looking Ahead

 In addition to the broad acceptance that AT has gained for QC/NDT of composite materials, it is proving to be useful for newer ceramic structures and coatings that are difficult to inspect with ultrasound. Dedicated AT signal processing methods have advanced far beyond the early hot / cold spot days, to a stage where quantitative measurement or depth or thermal properties rivals traditional methods for many applications. On the horizon, the combination of AT and AI may lead to a new generation of tools.

READ MORE

  • Thermal Imaging for Quality Control
  • Back to Basics: Thermography 101
  • Active Thermography for Nondestructive Composites Testing
KEYWORDS: infrared imaging manufacturing metrology thermography

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

Steven M. Shepard is president of Thermal Wave Imaging (Ferndale, MI). He can be reached at (248) 414-3730. [email protected]. www.thermalwave.com

Recommended Content

JOIN TODAY
to unlock your recommendations.

Already have an account? Sign In

  • 2024 Quality Rookie of the Year Justin Wise 1440x750px banner with "Quality Rookie of the Year" logo inset

    Meet the 2024 Quality Rookie of the Year: Justin Wise

    Justin Wise is an exceptional individual who has been...
    Aerospace
    By: Michelle Bangert
  • Man with umbrella and coat stands outside while it rains at night looking at a building.

    Nondestructive Testing: Is there an ethics problem?

    I was a whistleblower who exposed fraudulent activities...
    NDT
    By: Dale Norwood
  • Unraveling Deflategate: Football stadium with closeup of football on field

    Unraveling the Tom Brady Deflategate

    The Deflategate scandal erupted following the 2014 AFC...
    Measurement
    By: Greg Cenker and Henry Zumbrun
Subscribe For Free!
  • eMagazine Subscriptions
  • eNewsletters
  • Online Registration
  • Subscription Customer Service
  • Manage My Preferences

More Videos

Popular Stories

Technician working with the Vision Engineering LVC200.

Difference Between Calibration and Verification

Woman working in quality control, measuring a workpiece.

AI’s Double-Edged Sword: Security and Compliance in Manufacturing

QM0525-FEAT-A3-Automation-p1FT-Quality-Inspection.jpg

The Next Frontier of Automation: Quality Assurance in an AI-Driven Era

May 21 Quality Hexagon Live Webinar

Events

May 21, 2025

The Evolution of Laser Radar: Measuring Large Scale From Distance With High Accuracy

This webinar, featuring a live demonstration, will showcase the evolution of Hexagon’s direct scanning laser trackers: cutting-edge technology that now delivers traditional reflector-tracking accuracy to non-contact, large-part scanning.

View All Submit An Event

Products

Lean Manufacturing and Service Fundamentals, Applications, and Case Studies

Lean Manufacturing and Service Fundamentals, Applications, and Case Studies

See More Products
Play Quality's captivating word-guessing game! There's a new word every Friday.

Related Articles

  • Thermography of Turbine Airfoils

    See More
  • Advances in Pulsed Thermography

    See More
  • Flash Thermography The Final Frontier

    See More

Related Directories

  • Criterion NDT Inc.

    USA based manufacturer of Eddy Current instrumentation and sensors that Detect and Sort rejectable products in-line. A globally accepted methodology used to provide quality inspection of manufactured components for the Automotive, Industrial, Aerospace and Medical markets. Validating machining, forming, broaching, threading, assembly and heat treatment processes in real-time.
  • Vision Engineering Inc.

    A small defect, invisible to the naked eye, could cause serious complications. Our patented optical and digital systems and technologies are used in every stage of the manufacturing process. From design, prototyping, goods in, production, and inspection, Vision Engineering systems help companies across the world achieve quality standards.
×

Stay in the know with Quality’s comprehensive coverage of
the manufacturing and metrology industries.

eNewsletter | Website | eMagazine

JOIN TODAY!
  • RESOURCES
    • Advertise
    • Contact Us
    • Directories
    • Store
    • Want More
  • SIGN UP TODAY
    • Create Account
    • eMagazine
    • eNewsletter
    • Customer Service
    • Manage Preferences
  • SERVICES
    • Marketing Services
    • Market Research
    • Reprints
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • YouTube
    • X (Twitter)
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2025. All Rights Reserved BNP Media.

Design, CMS, Hosting & Web Development :: ePublishing